2018 Product Catalog

134 Voltage Polarity Part # Part # PFQ 300** PF300 PFQ 300** PF300 277V 1P+N+G 47-34045 49-34045 47-38045 49-38045 347V 1P+N+G 47-34145 49-34145 47-38145 49-38145 480V 2P+G 47-34042 49-34042 47-38042 49-38042 480V 2P+N+G 47-34046 49-34046 47-38046 49-38046 480V 3P+G 47-34043 49-34043 47-38043 49-38043 480V 3P+N+G 47-34047 49-34047 47-38047 49-38047 600V 2P+G 47-34142 49-34142 47-38142 49-38142 600V 2P+N+G 47-34146 49-34146 47-38146 49-38146 600V 3P+G 47-34143 49-34143 47-38143 49-38143 600V 3P+N+G 47-34147 49-34147 47-38147 49-38147 ** PFQ300 devices are differentiated from similarly rated PF300 devices in their smaller size, lighter weight and different pilot contacts. For international configurations and ratings (IEC,CE) visit meltric.com/ international-catalog or contact customer service at 800.433.7642. Voltage Polarity Part # Part # PF400 PF600 PF400 PF600 277V 1P+N+G 49-44045 49-64045 49-48045 49-68045 347V 1P+N+G 49-44145 49-64145 49-48145 49-68145 480V 2P+G 49-44042 49-64042 49-48042 49-68042 480V 2P+N+G 49-44046 49-64046 49-48046 49-68046 480V 3P+G 49-44043 49-64043 49-48043 49-68043 480V 3P+N+G 49-44047 49-64047 49-48047 49-68047 600V 2P+G 49-44142 49-64142 49-48142 49-68142 600V 2P+N+G 49-44146 49-64146 49-48146 49-68146 600V 3P+G 49-44143 49-64143 49-48143 49-68143 600V 3P+N+G 49-44147 49-64147 49-48147 49-68147 For international configurations and ratings (IEC,CE) visit meltric.com/ international-catalog or contact customer service at 800.433.7642. UL/CSA Ratings PF/PFQ High Ampacity Plugs & Receptacles 300A-600A • Max Amperage & Voltage PF = 600A, 1000 VAC*, 250 VDC PFQ = 300A, 600 VAC, 250 VDC • Current Interruption Capability Not for current interrupting • Environmental Ratings IP66/IP67 • Temperature Range Min -40°F/Max 140°F See pg 253 for temps below -15°F. • Wiring Capacity PFQ = 2 AWG to 600 MCM PF = 2 AWG to 600 MCM • Certifications UL 1682*, CSA 182.1* * Listings apply only to 300A & 400A devices at 600V or less ! PF/PFQ devices are not intended for connection or disconnection under load. To prevent live making or breaking electrical interlocking is required. Receptacle/Cap 300A (female) Receptacle/Cap 400A/600A (female) Inlet/Cap 300A (male) Inlet/Cap 400A/600A (male) North American UL/CSA Configurations North American UL/CSA Configurations PFQ shown PFQ shown Main Options Part # Receptacle with no cap Recept # - 48 Receptacle with lockout hole Recept # - 843 Inlet with no cap Inlet # - 48 Receptacle with lockout hole Inlet # - 843 Notes: • Metal caps are provided as standard with male and female devices. • Heat shrink wrap is provided with each inlet and receptacle to provide insulation between terminals. • Lugs are not included . The PF and PFQ contacts utilize bolt-on lug type wire terminals, which require a compression lug with a 9/16” or 5/8” hole. The angled handle requires straight lugs; the straight handle requires 90° lugs. ! See pages 230-239 for detailed information on these options ! Don’t forget to add installation accessories to your order

RkJQdWJsaXNoZXIy OTk3MQ==