2018 Product Catalog

46 Voltage Polarity Part # Part # Poly Metal Poly Metal 120V 1P+N+G 33-64235-C-K16 37-64235-C-K16 33-68235-C-K16 37-68235-C-K16 120 208V 3P+N+G 33-64237-C-K16 37-64237-C-K16 33-68237-C-K16 37-68237-C-K16 125V 1P+N+G 33-64175-C-K07 37-64175-C-K07 33-68175-C-K07 37-68175-C-K07 125 250V 2P+N+G 33-64176-C-K07 37-64176-C-K07 33-68176-C-K07 37-68176-C-K07 208V 2P+G 33-64232-C-K16 37-64232-C-K16 33-68232-C-K16 37-68232-C-K16 208V 3P+G 33-64233-C-K16 37-64233-C-K16 33-68233-C-K16 37-68233-C-K16 250V 2P+G 33-64172-C-K07 37-64172-C-K07 33-68172-C-K07 37-68172-C-K07 250V 3P+G 33-64173-C-K07 37-64173-C-K07 33-68173-C-K07 37-68173-C-K07 277V 1P+N+G 33-64245-C-K04 37-64245-C-K04 33-68245-C-K04 37-68245-C-K04 277 480V 3P+N+G 33-64247-C-K04 37-64247-C-K04 33-68247-C-K04 37-68247-C-K04 347 600V 3P+N+G 33-64187-C-K14 37-64187-C-K14 33-68187-C-K14 37-68187-C-K14 480V 2P+G 33-64242-C-K04 37-64242-C-K04 33-68242-C-K04 37-68242-C-K04 480V 3P+G 33-64243-C-K04 37-64243-C-K04 33-68243-C-K04 37-68243-C-K04 600V 2P+G 33-64182-C-K14 37-64182-C-K14 33-68182-C-K14 37-68182-C-K14 600V 3P+G 33-64183-C-K14 37-64183-C-K14 33-68183-C-K14 37-68183-C-K14 For international configurations and ratings (IEC,CE) visit meltric.com/ international-catalog or contact customer service at 800.433.7642. UL/CSA Ratings DS 100C Switch-Rated Plugs & Receptacles – 100A • Max Amperage & Voltage 100A, 600 VAC • Switch-Ratings (AC Only) Branch Circuit & Motor Circuit Disconnect Switching • Horsepower Ratings 1Ø 5 hp 1Ø 10 hp 3Ø 20 hp 3Ø 20 hp 3Ø 50 hp 3Ø 50 hp • Short Circuit Rating 100kA Close & Withstand Tested with RK1 current limiting fuses sized at 400% of the highest full load motor ampacity. • Environmental Ratings Type 3R (Standard) Type 4X (Optional) • Temperature Range Min -40°F/Max 140°F See pg 253 for temps below -15°F. • Wiring Capacity Min 10 AWG Max 2 AWG Aux Contacts - Max 14 AWG Based on THHN wire sizes • Certifications UL 2682, UL 1682, CSA 182.1 Receptacle Options Suffix # Inlet Options Suffix # With 2 Auxiliary/Pilot Contacts Recept # - 972 With 2 Auxiliary/Pilot Contacts Inlet # - 972 With 3 Auxiliary/Pilot Contacts Recept # - 263 With 3 Auxiliary/Pilot Contacts Inlet # - 263 With 4 Auxiliary/Pilot Contacts Recept # - 264 With 4 Auxiliary/Pilot Contacts Inlet # - 264 Type 4X & closed lid configuration Recept # - 4X Type 4X watertightness Inlet # - 4X Straight Insertion Recept # - 352 Self-Ejecting Plug Release Inlet # - 338 Self-Ejecting Connector Release Recept # - 354 With No Lockout Hole Inlet # - A155 Mushroom Pawl Recept # - 375 For Auxiliary Switch* Inlet # - NNF Padlock Pawl Recept # - 843 Notes: * Order inlet with P+N+G configuration and receptacle with P+G configuration. Padlockable Mushroom Pawl Recept # - 375-843 Locking Mushroom Pawl Recept # - 845 Metal Pawl (on poly receptacle) Recept # - 824 Closed Lid Configuration Recept # - NC With Auxiliary Switch Recept # - 270+ 180° Opening Lid (metal only) Recept # - 180++ Notes: + Not UL/CSA listed. ++ Required when mating to rigid mounted male inlet. Order Example: 480V DS100C + 2 auxiliary contacts DS100C Poly inlet 3P+G = 33-68243-C-K04 -972 Main Options Auxiliary/Pilot Contacts Mushroom Pawl Padlock Pawl Closed Lid Configuration Recommended for cord applications to keep lid tucked in to avoid damage. 5/16” hole 120V 240V 208V 240V 480V 600V Receptacle (female) Inlet (male) North American UL/CSA Configurations ! See pages 230-239 for detailed information on these options ! Don’t forget to add installation accessories to your order

RkJQdWJsaXNoZXIy OTk3MQ==