Decontactor™ Series Switch Rated Plugs & Receptacles

Pump Connectors

lockout pumps with Meltric plugs and receptacles
Pump disconnect switch rated plugs and receptacles
secondary sludge pump disconnect switch rated plug and connectors
pasteurizer industrial pump plugs and receptacles

Simplify Pump Servicing

Decontactor plugs and receptacles are ideal for pump connections up to 60 hp or 200 amps. Using Decontactors to connect power to pumps instead of hard-wiring can reduce downtime related to pump servicing by 50% or more. A qualified technician can safely disconnect power to the pump simply by removing the Decontactor plug which can then be easily locked out to ensure safety. The technician can then service the pump in complete safety. When service work is complete the technician can reconnect power simply by plugging the Decontactor plug back into the receptacle.

motor connect and disconnect

  • No waiting for an electrician to perform field wiring
  • No “suiting-up” or extraordinary electrical precautions

Safely Make/Break Motor Connections, Even
During Overloads

Decontactor plugs and receptacles are designed and rated to make and break motor loads in complete safety while providing users with significant protection in the event of overloads or short circuits. Special protective equipment and training are not required to make and break connections.

submersible pump electrical plug and connector

  • Overload testing includes 50 opening and closing operations performed at 600% of full load motor ampacity with a power factor of 0.5 or less.

  • All hp-rated Decontactor devices are rated to close into and withstand short circuit currents up to 100kA in circuits protected with RK1 fusing.

Note: Although Decontactor plugs and receptacles are rated to safely make and break motor loads, they are not rated or intended for continuous use as a motor starter.


Easily Locate "Line of Sight" Disconnects Using Mounting Options

Meltric Decontactor plug and receptacle quick connect 230V connector and plug 230V motor plug

Sections 430.102 – 430.109 of the National Electric Code require approved disconnecting means to be located in a readily accessible location within sight of the motor and driven equipment. With their UL & CSA ratings for “Motor Circuit Disconnect Switching” and “Branch Circuit Disconnect Switching”, Decontactor devices are an approved ‘line of sight’ disconnect switch for meeting this requirement.


Decontactor plugs and receptacles are available with numerous handles, mounting angles, wall boxes, and other accessories. They may be used as in-line connectors or may be mounted on walls, panels, equipment, or even directly on the motor. This flexibility makes it simple to locate disconnects where they are easily visible
and convenient to use.


Reduce Improper Motor Rotation with Pre-wired Replacements

electrical motor test bench with Meltric receptacle

Replacement motors that are pre-wired and tested with appropriately phased receptacles in the service center will automatically provide the desired direction of rotation when connected (plugged in) on site. Pre-wiring and testing eliminates the need to jog the motor and avoids additional downtime and production problems resulting from improper rotation.




Monitor Motor Temperature Using Built-in Auxiliary Contacts

decontactor plug

Optional integral auxiliary contacts can be used to communicate motor temperatures back to a control center so preventative maintenance can be performed before motor failure occurs.